Non-contact Uncured Powder Thickness Gage
Affordably measures uncured powder coatings using non-contact ultrasonic technology to predict a cured thickness
Conforms to ASTM D7378
Simple
Durable
Accurate
Versatile
Powerful
Complete solutions for measuring powder coatings before and after cure.
Each Powder Inspection Kit contains:
Custom Inspection Kits
DeFelsko Powder Comb (included)
|
![]() |
Kits come complete
with
Case Size
30 cm (l) x 25 cm (w) x 10 cm (d)
12 inch (l) x 10 inch (w) x 4 inch (d)
Weight
1.3 kg (2.8 lbs.)
Base Unit
Probe
Gage Comes Complete
|
![]() |
PosiTector PC | PosiTector Powder Inspection Kits | ||||
![]() |
|
||||
Order Code |
PC3-E | KITPCF3 | KITPCFS3 | KITPCFN3 | KITPCFNS3 |
PosiTector body | Advanced | Advanced | |||
PosiTector PC probe | PRBPC | PRBPC | |||
PosiTector 6000 probe | Not Included |
6000-F (ferrous only) |
6000-FS (ferrous only, with cable) | 6000-FN (ferrous & non-ferrous) |
6000-FNS (ferrous & non-ferrous with cable) |
Powder Combs | Not Included |
Model 1 |
Model 1 Model 4 |
Model 1 Model 4 |
Model 1 Model 4 |
Protective Rubber Holster | Included | Included | |||
Hard Shell Case | Included | Included |
Q. Are there different models of the PosiTector PC to choose from?
A. No. There is 1 model consisting of an Advanced gage body and probe (ordering code: PC3-E). You can purchase the probe separately (ordering code: PRBPC) for use with Advanced
gage bodies with serial numbers greater than 700,000 (manufactured after April 2011).
Q. What has changed from the previous versions?
A. The PosiTector PC probe remains unchanged with the same range, resolution and accuracy. The PosiTector PC contains all of the ââ¬â¹features of the Advanced gage body
including...
Q. Can I purchase a new PosiTector PC probe for my existing PosiTector Advanced gage body?
A. Yes. PosiTector Advanced gage bodies manufactured after April 2011 with serial numbers greater than 700,000 support the NEW PosiTector PC probe. Simply update your existing
PosiTector by following step by step instructions at www.defelsko.com/update. The PosiTector PC probe will NOT work on Standard gage bodies.
Q. Can I use my previous generation PosiTector PC probe on my new model PosiTector gage body?
A. Yes. A quick reset will allow the PC probe to communicate with all new gage bodies. Once reset, however, the PC probe will be unable to communicate with the previous generation
gage body unless both are returned for service.
Q. Can I connect other probes?
A. Yes. The PosiTector PC accepts all PosiTector probes easily converting from measuring uncured powder to cured dry film thickness, surface profile, and more.
Q. What are the optional accessories?
A. Replacement Probe Screens (Qty. 2) to protect the probe transducer, Bluetooth Printer battery-operated printer receives measurement data, AC Power Cable provides
continuous operation or battery charging works in any country, Rechargeable Batteries a set of eneloop NiMH AAA batteries, Hard Shell Inspection Case durable carry case, Protective Lens Shield (Pkg
of 5) protect the display from overspray
Q. Does the PosiTector PC conform to existing standards and test methods?
A. Yes. The PosiTector PC complies with ASTM D7378, Standard Practice for Measurement of Thickness of Applied Coating Powders to Predict Cured Thickness.
Q. Why measure uncured powder?
A. Coatings must be applied within certain minimum and maximum dry film thickness specifications. But waiting to measure coating thickness after curing can result in product waste
and production delays. Accurate measurement at the time of application:
Q. Can I purchase a complete solution for measuring powder coating before and after cure?
A. Yes. NEW PosiTector Powder Inspection Kits are available. Each kit contains a PosiTector Advanced gage body, PosiTector PC uncured powder thickness probe, user-selected
PosiTector 6000 coating thickness probe and the 2 most popular DeFelsko Powder Combs.
Q. How do you operate the PosiTector PC?
A. Turn both the probe and gage body on, press the probe button and hold it 18 mm (0.75ââ¬Â) from the part for 2 to 5 seconds. The predicted cured thickness result immediately
appears on both the probe and gage body displays.
Q. How does it work?
A. The probe uses ultrasound to non-destructively analyze applied powder in seconds. Information passes between the probe and the gage body via a fast Bluetooth wireless
connection.
Q. Is there a Certificate of Calibration?
A. No. Certificates of Calibration show traceability to a National Standard and no dry powder thickness standard exists at this time. The PosiTector PC Powder Checker is an
in-process tool. To confirm final thickness meets specification, measure the cured coating with a PosiTector 6000 dry film thickness probe. A Certificate of Calibration is included with every
PosiTector 6000 probe.
Q. Can the PosiTector PC store or print data?
A. Yes. The PosiTector PC features PosiSoftî USB Drive for storing readings and to download stored readings to a PC or Mac. Additionally, readings can be synchronized with
PosiSoft.net (formerly PosiTector.net) for storing, printing or sharing with authorized users. Also features data transfer via WiFi to a personal computer or via Bluetooth to a personal computer or
optional Bluetooth printer.
Q. What is PosiSoft.net?
A. A cloud based web application offering secure centralized management of thickness readings. It allows the user to upload readings, download images, manipulate data, generate
reports and graphs, share data with other authorized users, and export data to XML and text files. See http://www.defelsko.com/PosiSoftNET/ for more details.
Q. Are there alternative ways to measure uncured powder?
A. Yes. Handy, inexpensive powder combs are available. Coating powders diminish in thickness during the curing process, so measuring powder height in the pre-cured, pre-gelled
state requires a correlation factor be calculated and applied to every measurement for every powder. Two popular Powder Comb models are included with each PosiTector Powder Inspection
Kit.
Q. Can I measure cured powder thickness with the PosiTector post cure?
A. Yes. Simply connect a PosiTector 6000 dry film thickness probe to measure the cured powder coating thickness.
Q. Does the PosiTector PC imprint or dimple the powder?
A. No contact is made during measurement and there are no cables to accidentally brush and disturb the powder.
Q. How far away can the wireless probe be from the gage body to measure remotely?
A. The wireless probe has a range of 10m (30 ft.).
Q. What happens if I move the probe further than 10m (30ft) from the gage body?
A. Communication between both units will temporarily cease if they are moved beyond radio range of each other. The probe will simply stop working but will resume operation when
brought back within radio range of the gage body.
Q. How do I know that the gage body has received my readings?
A. The instrument will not operate unless the probe and gage body are communicating with each other. Set-up is simple. Each measurement result is displayed on both the probe and
gage body. Both units beep and flash simultaneously. Both will power-down automatically after a period of no activity.
Q. Can I pair the probe with another Bluetooth device?
A. No. The data transmitted between the probe and the gage body is secure . Neither the probe nor gage body can be paired with another Bluetooth device. The probe will only
communicate with an Advanced gage body.
Q. Do I have to hold the probe steady during measurement?
A. No. In fact, the instrument performs best when there is slight movement. It was designed to measure moving parts on hooks.
Q. When measuring, the result on the probe and gage body occasionally changes by several digits after I remove my finger from the probe. Is this
OK?
A. Yes, this is normal operation. There is a queue of samples that are still being processed after the button is released.
Q. What types of batteries are used?
A. The wireless probe uses 3 AA alkaline batteries. The gage body uses 3 AAA alkaline batteries. Battery icons display a full bar with fresh alkaline batteries installed. As the
batteries weaken, the bar will be reduced. When the battery icon is low, the instrument can still be used, but the batteries should be changed at the earliest opportunity.
PC Powder Checker | |
---|---|
PosiTest PC Kit DFT-Combo - Inspection Kit with Case |
|
PosiTest PC Kit DFT-Ferrous - Inspection Kit with Case |
|
PosiPosiTest PC Kit FNS1 Standard - Inspection Kit with Case | |
PosiTest PC Kit FNS3 Advanced - Inspection Kit with Case |
|
PosiTest PC Kit FS1 Standard - Inspection Kit with Case |
|
PosiTest PC Kit FS3 Advanced - Inspection Kit with Case |
|
Probe Screens (package of 2) - for Powder Thickness Gage |
![]() |
PosiTector Probes PosiTector body accepts all PosiTector 6000, 200, DPM, UTG, RTR and SPG probes easily converting from a coating thickness gage to a dew point meter, surface profile gage or wall thickness gage |
![]() |
Replacement Probe Screens Used to protect the probe transducer (Qty. 2)
|
|
Bluetooth Printer receives data from Advanced models
|
![]() |
AC Power Cable for continuous operation or battery charging
This kit supplies several alternate power solutions for your battery-operated PosiTector. They allow the gage to operate continuously without the need for batteries. Use the cable alone to connect a PosiTector to your PCs built-in USB port that acts as a continuous power source. Or connect the cable to the included power adaptor which plugs into any AC wall electrical outlet, 110 or 220V. A selection of electrical plugs is included which are capable of dealing with most countrys outlets. |
![]() |
PosiTector Case Convenient hard shell case for carrying a PosiTector gage body and multiple probes - including any of the PosiTector 6000 Coating Thickness probes, DPM Dew Point Meter probes, SPG Surface Profile probes, or UTG Ultrasonic Wall Thickness probes. Case has compartments for Certificates of Calibration, instruction manuals and other accessories. |
![]() |
Protective Lens Shield
One lens shield is included with every PosiTector instrument |
CALL 800-458-3687 X1 FOR AVAILABILITY & FREE 2ND DAY AIR DETAILS OR ADD TO CART
CALL 800-458-3687 X1 FOR AVAILABILITY & FREE 2ND DAY AIR DETAILS OR ADD TO CART