The PSS90 is equipped with a 8-cylinder OHV TCAC GM, liquid cooled engine that can run off LP or NG. The PSS90 is available in single and three phase configurations.
ENGINE FEATURES
The 4 cylinder, overhead valve GM 3.0L engine meets EPA/Carb Emission Regulations for LSI Engines. All engine functions are controlled by an engine mounted ECM. The engine features include an
electronic ignition, engine blockheater and vapor fuel system. A critical grade muffler is installed to reduce engine noise levels. Battery rack, cables, and battery tender (charger) are factory
installed. A BCI Group 24 650 CCA battery must be purchased separately. Engine cooling is provided by a unit mount radiator. The engine is equipped with a belt driven pusher type fan.
GENERATOR FEATURES
The generator is a single bearing rotating field generator mounted to the engine flywheel via dual flex drive discs. Three phase generators have 12 lead broad range reconnectable stators; single
phase generators are 4 lead. An external voltage regulator maintains proper voltage output, accurate to +/- 1%. The engine generator combination has the ability to start and operate motors up to 8
hp Code G. Mainline circuit breaker included for generator protection.
OPTIONAL Excitation Boost System available.
Specifications | ||||
---|---|---|---|---|
MODEL NUMBER | PSS90-4 | PSS90-17 | PSS90-18 | |
STANDBY RATING POWER OUTPUT (60HZ) | 120/208V, 3-Phase, .8 p.f. | 120/240V, 3-Phase, .8 p.f. | 277/480V, 3-Phase, .8 p.f. | |
KW (L.P. GAS) | 80 | 80 | 80 | |
KVA (L.P. GAS) | 100 | 100 | 100 | |
AMPS (L.P. GAS) | 278 | 240 | 120 | |
CB AMPS (L.P. GAS) | 300 | 250 | 125 | |
KW (NATURAL GAS) | 90 | 90 | 90 | |
KVA (NATURAL GAS) | 112 | 112 | 112 | |
AMPS (NATURAL GAS) | 312 | 270 | 135 | |
CB AMPS (NATURAL GAS) | 300 | 250 | 125 | |
Derating Factors: Temperature - No derate up to 122 degrees F; Elevation - 3.5% per 1,000 feet elevation above 6,500 feet |
No Listed Accessories