DIGITAL COATING THICKNESS GAUGE
MODEL NO. PTG-1000
Features
-
The PHASE II PTG-1000 can
perform two different methods of calculating Coating
thickness measurement by utilizing the characteristics
of both eddy current and magnetic induction.
-
Both non-destructively
and very accurately.
-
By attaching the
appropriate probe (F-or N-type) you can detect either
the thickness of nonmagnetic coating on a magnetic
substrate or an insulating coating on a non-magnetic
conductive substrate.
-
The PTG-1000 provides two
operating modes: direct and application/batch(this mode
stores both calibration setting and readings taken).
-
The memory has a storage
capacity for up to 3000 readings.
-
Five different
statistical parameters can be calculated, displayed and
printed.
-
Using a special
calibrating method the thickness of a chromic coating on
a copper substrate can be measured.
-
The PTG-1000 also
provides a Calibration-through-coating (CTC) feature
when only one coated substrates are available for
measurement. Also by attaching a special CN200-probe,
the thickness of non-magnetic conductive coating
(copper, aluminum) on an insulating substrate(plastics,
print boards) can be measured.
|
Main Functions
-
Ten types of probes are
available to cover a whole range of special measurement
requirements: F-probes (ferrous) and N-probes
(non-ferrous)
-
Four methods can be used
to calibrate the COATER
-
Special feature:
Calibration Through Coating (CTG)
-
Five different
statistical parameters can be calculated, displayed and
printed
-
Two measuring modes can
be selected: continuous and single
-
Two operating modes are
provided: direct and application/batch
-
The memory has a storage
capacity for up to 3000 readings
-
Histogram can be printed
out for further analysis for measured values
-
Limits can be set,
outside limit warning will be given
-
Automatic or manual
switch off
-
Easy deletions of wrong
settings or readings
-
Retrieval and print out
of stored readings if desired
-
Buzz prompts next step of
operation
-
Low battery indicator
-
Errors during operation
indicated by buzzing and error codes on LCD
-
Instrument can be used
with or without the integral / removable printer
|
SPECIFICATIONS |
Measuring Range |
0-10.000 m m max |
Guaranteed Tolerance:
|
+- 1%H +1 m m (where H = nominal
value) |
Min. Substrate Thickness |
F1-probe 0.5mm
N1-probe 0.3mm |
Min Diameter of Substrate |
F1-probe 3mm
N1-probe 6mm |
Operating Temperature |
32-113 degrees F (0-45 degrees C) |
Surface Temperature of Test Object |
302 degrees F
(contact time max is 2 seconds) |
Power Source |
4 x 1.25V NiMH batteries |
Dimensions (LxWxH) |
10.6 x 3.4 x 1.8in. (270 x 86 x
47mm) |
Weight |
1.4lbs (650g) |
|
|
|
There are no further details.
There are no further specifications.
There is no further information.
There are no listed accessories.