Technical Sales 1–800–458–3687

DeFelsko PosiTector 6000 Probe Details

Select from a variety of measurement ranges and probe styles

The PosiTector 6000 consists of a Gage body and a probe. A wide selection of interchangeable probes are available. All Gage bodies accept all probes. Video Overview 

s-h alt

s-h alt
  • Two (2) year probe warranty
  • Heavy-duty, gold-plated locking connector for industrial environments
  • Certificate of Calibration (Long Form) traceable to NIST included with every probe
  • Each probe retains its own unique calibration information (allowing full probe interchangeability)
  • Extended cables available for underwater or remote measuring. Specify length when ordering

 

Probe Ordering Guide:

F - for ferrous metals (steel and cast iron)
N - for non-ferrous metals (aluminum, copper, titanium, etc.)
FN - for all metal substrates - Automatically recognizes the substrate and takes a measurement

PROBE MODEL Substrates Probe Style Measuring Range
F ferrous removable built-in 0 - 60 mils (0 - 1500 um)
FS ferrous regular separate 0 - 60 mils (0 - 1500 um)
FRS ferrous 90° regular separate 0 - 60 mils (0 - 1500 um)
F0S ferrous 0° microprobe 0 - 45 mils (0 - 1150 um)
F45S ferrous 45° microprobe 0 - 45 mils (0 - 1150 um)
F90S ferrous 90° microprobe 0 - 45 mils (0 - 1150 um)
FT ferrous removable built-in 0 - 250 mils (0 - 6 mm)
FTS ferrous high-range separate 0 - 250 mils (0 - 6 mm)
FKS ferrous high-range separate 0 - 500 mils (0 - 13 mm)
N non-ferrous removable built-in 0 - 60 mils (0 - 1500 um)
NS non-ferrous regular separate 0 - 60 mils (0 - 1500 um)
NRS non-ferrous 90° regular separate 0 - 60 mils (0 - 1500 um)
NAS non-ferrous regular separate 0 - 25 mils (0 - 625 um)
N0S non-ferrous 0° microprobe 0 - 25 mils (0 - 625 um)
N45S non-ferrous 45° microprobe 0 - 25 mils (0 - 625 um)
N90S non-ferrous 90° microprobe 0 - 25 mils (0 - 625 um)
NKS non-ferrous high-range separate 0 - 500 mils (0 - 13 mm)
FN ferrous / non-ferrous combo removable built-in 0 - 60 mils (0 - 1500 um)
FNS ferrous / non-ferrous combo regular separate 0 - 60 mils (0 - 1500 um)
FNRS ferrous / non-ferrous combo 90° regular separate 0 - 60 mils (0 - 1500 um)
TNTS ferrous / non-ferrous combo high-range separate 0 - 250 mils (0 - 6 mm)

Probe Details


s-h alt

Removable Built-in probes
(F, N, FN, FT)

Ideal for one-handed operation.

   
Removable
Built-in Probe
Probe Model:
F
N
FN
FT
s-h alt
Range:
0 - 60 mils 0 -250 mils
0 - 1500 um 0 - 6 mm
Accuracy*:
+ (0.05 mils + 1%)  0 - 2 mils
   + (0.1 mils  +  1%)  > 2 mils
+ (0.5 mils + 1%)  0 - 100 mils
 + (0.5 mil + 3%) > 100 mils
+ (1 um + 1%)  0 - 50 um
 + (2 um + 1%)  > 50 um

 + (0.01 mm + 1%) 0 - 2.5 mm
+ (0.01 mm + 3%) > 2.5 mm

*Accuracies are stated as a fixed value plus a percentage of the gage's actual reading.

 

 

 

Separate Regular Probes
(FS, NS, FNS, NAS, FTS)

These constant-pressure, stainless steel probes are hermetically sealed to be totally waterproof - ideal for underwater use.

   
Regular
Probe Model:
FS
NS
FNS
NAS
FTS
s-h alt
Range:
0 - 60 mils 0 -25 mils 0 -250 mils
0 - 1500 um 0 - 625 um 0 - 6 mm
Accuracy*:
+ (0.05 mils + 1%)  0 - 2 mils
   + (0.1 mils  +  1%)  > 2 mils
+ (0.02 mils + 1%)  0 - 4 mils
 + (0.1 mils + 3%)  > 4 mils
+ (0.5 mils + 1%)  0 - 100 mils
 + (0.5 mil + 3%) > 100 mils
+ (1 um + 1%)  0 - 50 um
 + (2 um + 1%)  > 50 um
+ (.5 um + 1%)  0 - 100 um
 + (2 um + 3%)  > 100 um 

 + (0.01 mm + 1%) 0 - 2.5 mm
+ (0.01 mm + 3%) > 2.5 mm

*Accuracies are stated as a fixed value plus a percentage of the gage's actual reading.

 

 

 

s-h alt

 

Separate 90° Regular Probes
(FRS, NRS, FNRS)

Right angle probe for measuring within areas of low headroom.

These constant-pressure, stainless steel probes are hermetically sealed to be totally waterproof - ideal for underwater use.

   
90 Regular
Probe Model:
FRS
NRS
FNRS
s-h alt
Range:
0 - 60 mils
0 - 1500 um
Accuracy*:
+ (0.05 mils + 1%)  0 - 2 mils
   + (0.1 mils  +  1%)  > 2 mils
+ (1 um + 1%)  0 - 50 um
 + (2 um + 1%)  > 50 um
*Accuracies are stated as a fixed value plus a percentage of the gage's actual reading.

 

 

 

Separate 0° Microprobes
(F0S, N0S)

With our smallest measuring tip and best thin-film accuracy, this instrument is ideal for measuring on small parts, hard-to-reach areas, or close to edges.

The straight F0S and N0S Microprobes have a quick release adapter that makes them constant pressure probes for alignment on small, flat or curved parts. This adapter is held in place by a spring. If the sleeve is not required, simply pull it off the probe.
   
0 Microprobe
Probe Model:
F0S
N0S
s-h alts-h alt
Range:
0 - 45 mils 0 - 25 mils
0 - 1150 um 0 - 625 um
Accuracy*:
+ (0.02 mils + 1%)  0 - 4 mils
 + (0.1 mils + 3%)  > 4 mils
+ (.5 um + 1%)  0 - 100 um
 + (2 um + 3%)  > 100 um  
*Accuracies are stated as a fixed value plus a percentage of the gage's actual reading.

s-h alt

Separate 45°Microprobes
(F45S, N45S)

With our smallest measuring tip and best thin-film accuracy, this instrument is ideal for measuring on small parts, hard-to-reach areas, or close to edges.

   
45 Microprobe
Probe Model:
F45S
N45S
s-h alt
Range:
0 - 45 mils 0 - 25 mils
0 - 1150 um 0 - 625 um
Accuracy*:
+ (0.02 mils + 1%)  0 - 4 mils
 + (0.1 mils + 3%)  > 4 mils
+ (.5 um + 1%)  0 - 100 um
 + (2 um + 3%)  > 100 um  
*Accuracies are stated as a fixed value plus a percentage of the gage's actual reading.

 

 

 

Separate 90° Microprobes
(F90S, N90S)

Right angle probe for measuring within areas of low headroom.

With our smallest measuring tip and best thin-film accuracy, this instrument is ideal for measuring on small parts, hard-to-reach areas, or close to edges.

   
90 Microprobe
Probe Model:
N90S
s-h alt
Range:
0 - 45 mils 0 - 25 mils
0 - 1150 um 0 - 625 um
Accuracy*:
+ (0.02 mils + 1%)  0 - 4 mils
 + (0.1 mils + 3%)  > 4 mils
+ (.5 um + 1%)  0 - 100 um
 + (2 um + 3%)  > 100 um  
*Accuracies are stated as a fixed value plus a percentage of the gage's actual reading.

 

 

s-h alt

 

High-Range Probes
(FT, FTS, FNTS, FKS, NKS)

Ideal for thick protective coatings such as epoxy, rubber, concrete liners, intumescent fireproofing and more.

   
High-Range
Probe Model:
FT
FTS
FNTS
FKS
NKS

s-h alt s-h alt
Range:
0 -250 mils 0 -500 mils
0 - 6 mm 0 - 13 mm
Accuracy*:
+ (0.5 mils + 1%)  0 - 100 mils
 + (0.5 mil + 3%) > 100 mils

+ (1 mils + 3%) 
0 - 500 mils

 + (0.02 mm + 3%) 
0 - 13 mm

 + (0.01 mm + 1%) 0 - 2.5 mm
+ (0.01 mm + 3%) > 2.5 mm

FT FTS FNTS,FKS,NKS *Accuracies are stated as a fixed value plus a percentage of the gage's actual reading.

Probe Details: Several probe configurations are available for measuring a wide variety of coating thickness application.

 

 Removable Built-in probes

Removable
Built-in Probe
Probe Model:
F
N
FN
FT
s-h alt
Range:
0 - 60 mils 0 -250 mils
0 - 1500 um 0 - 6 mm
Accuracy*:
+ (0.05 mils + 1%)  0 - 2 mils
   + (0.1 mils  +  1%)  > 2 mils
+ (0.5 mils + 1%)  0 - 100 mils
 + (0.5 mil + 3%) > 100 mils
+ (1 um + 1%)  0 - 50 um
 + (2 um + 1%)  > 50 um

 + (0.01 mm + 1%) 0 - 2.5 mm
+ (0.01 mm + 3%) > 2.5 mm

*Accuracies are stated as a fixed value plus a percentage of the gage's actual reading.

 

 Separate Regular Probes (below regular probes suitable for underwater use)

Regular
Probe Model:
FS
NS
FNS
NAS
FTS
s-h alt
Range:
0 - 60 mils 0 -25 mils 0 -250 mils
0 - 1500 um 0 - 625 um 0 - 6 mm
Accuracy*:
+ (0.05 mils + 1%)  0 - 2 mils
   + (0.1 mils  +  1%)  > 2 mils
+ (0.02 mils + 1%)  0 - 4 mils
 + (0.1 mils + 3%)  > 4 mils
+ (0.5 mils + 1%)  0 - 100 mils
 + (0.5 mil + 3%) > 100 mils
+ (1 um + 1%)  0 - 50 um
 + (2 um + 1%)  > 50 um
+ (.5 um + 1%)  0 - 100 um
 + (2 um + 3%)  > 100 um 

 + (0.01 mm + 1%) 0 - 2.5 mm
+ (0.01 mm + 3%) > 2.5 mm

*Accuracies are stated as a fixed value plus a percentage of the gage's actual reading.

 

90 Regular
Probe Model:
FRS
NRS
FNRS
s-h alt
Range:
0 - 60 mils
0 - 1500 um
Accuracy*:
+ (0.05 mils + 1%)  0 - 2 mils
   + (0.1 mils  +  1%)  > 2 mils
+ (1 um + 1%)  0 - 50 um
 + (2 um + 1%)  > 50 um
*Accuracies are stated as a fixed value plus a percentage of the gage's actual reading.

 Separate Microprobes

0 Microprobe
Probe Model:
F0S
N0S
s-h alts-h alt
Range:
0 - 45 mils 0 - 25 mils
0 - 1150 um 0 - 625 um
Accuracy*:
+ (0.02 mils + 1%)  0 - 4 mils
 + (0.1 mils + 3%)  > 4 mils
+ (.5 um + 1%)  0 - 100 um
 + (2 um + 3%)  > 100 um  
*Accuracies are stated as a fixed value plus a percentage of the gage's actual reading.

 

45 Microprobe
Probe Model:
F45S
N45S
s-h alt
Range:
0 - 45 mils 0 - 25 mils
0 - 1150 um 0 - 625 um
Accuracy*:
+ (0.02 mils + 1%)  0 - 4 mils
 + (0.1 mils + 3%)  > 4 mils
+ (.5 um + 1%)  0 - 100 um
 + (2 um + 3%)  > 100 um  
*Accuracies are stated as a fixed value plus a percentage of the gage's actual reading.

 

90 Microprobe
Probe Model:
F90S
N90S
s-h alt
Range:
0 - 45 mils 0 - 25 mils
0 - 1150 um 0 - 625 um
Accuracy*:
+ (0.02 mils + 1%)  0 - 4 mils
 + (0.1 mils + 3%)  > 4 mils
+ (.5 um + 1%)  0 - 100 um
 + (2 um + 3%)  > 100 um  
*Accuracies are stated as a fixed value plus a percentage of the gage's actual reading.

 Separate High-Range Probes

High-Range
Probe Model:
FNTS
FKS
NKS
s-h alt
Range:
0 -250 mils 0 -500 mils
0 - 6 mm 0 - 13 mm
Accuracy*:
+ (0.5 mils + 1%)  0 - 100 mils
 + (0.5 mil + 3%) > 100 mils
+ (1 mils + 3%)  0 - 500 mils
 + (0.02 mm + 3%) 0 - 13 mm

 + (0.01 mm + 1%) 0 - 2.5 mm
+ (0.01 mm + 3%) > 2.5 mm

*Accuracies are stated as a fixed value plus a percentage of the gage's actual reading.
Copyright © 2023 Smith-Hamilton, Inc
0.001 150419 18:39