Select from a variety of measurement ranges and probe styles
The PosiTector 6000 consists of a Gage body and a probe. A wide selection of interchangeable probes are available. All Gage bodies accept all probes. Video Overview
|
![]() |
Probe Ordering Guide:
F - for ferrous metals (steel and cast iron)
N - for non-ferrous metals (aluminum, copper, titanium, etc.)
FN - for all metal substrates - Automatically recognizes the substrate and takes a measurement
PROBE MODEL | Substrates | Probe Style | Measuring Range |
---|---|---|---|
F | ferrous | removable built-in | 0 - 60 mils (0 - 1500 um) |
FS | ferrous | regular separate | 0 - 60 mils (0 - 1500 um) |
FRS | ferrous | 90° regular separate | 0 - 60 mils (0 - 1500 um) |
F0S | ferrous | 0° microprobe | 0 - 45 mils (0 - 1150 um) |
F45S | ferrous | 45° microprobe | 0 - 45 mils (0 - 1150 um) |
F90S | ferrous | 90° microprobe | 0 - 45 mils (0 - 1150 um) |
FT | ferrous | removable built-in | 0 - 250 mils (0 - 6 mm) |
FTS | ferrous | high-range separate | 0 - 250 mils (0 - 6 mm) |
FKS | ferrous | high-range separate | 0 - 500 mils (0 - 13 mm) |
N | non-ferrous | removable built-in | 0 - 60 mils (0 - 1500 um) |
NS | non-ferrous | regular separate | 0 - 60 mils (0 - 1500 um) |
NRS | non-ferrous | 90° regular separate | 0 - 60 mils (0 - 1500 um) |
NAS | non-ferrous | regular separate | 0 - 25 mils (0 - 625 um) |
N0S | non-ferrous | 0° microprobe | 0 - 25 mils (0 - 625 um) |
N45S | non-ferrous | 45° microprobe | 0 - 25 mils (0 - 625 um) |
N90S | non-ferrous | 90° microprobe | 0 - 25 mils (0 - 625 um) |
NKS | non-ferrous | high-range separate | 0 - 500 mils (0 - 13 mm) |
FN | ferrous / non-ferrous combo | removable built-in | 0 - 60 mils (0 - 1500 um) |
FNS | ferrous / non-ferrous combo | regular separate | 0 - 60 mils (0 - 1500 um) |
FNRS | ferrous / non-ferrous combo | 90° regular separate | 0 - 60 mils (0 - 1500 um) |
TNTS | ferrous / non-ferrous combo | high-range separate | 0 - 250 mils (0 - 6 mm) |
Probe Details
![]() |
Removable Built-in probes Ideal for one-handed operation. |
Removable
Built-in Probe |
Probe Model:
|
F
|
N
|
FN
|
FT
|
![]() |
|||||
Range:
|
0 - 60 mils | 0 -250 mils | |||
0 - 1500 um | 0 - 6 mm | ||||
Accuracy*:
|
+ (0.05 mils + 1%) 0 - 2 mils + (0.1 mils + 1%) > 2 mils |
+ (0.5 mils + 1%) 0 - 100 mils + (0.5 mil + 3%) > 100 mils |
|||
+ (1 um + 1%) 0 - 50 um + (2 um + 1%) > 50 um |
+ (0.01 mm + 1%) 0 - 2.5 mm |
||||
*Accuracies are stated as a fixed value plus a percentage of the gage's actual reading. |
|
Separate Regular Probes These constant-pressure, stainless steel probes are hermetically sealed to be totally waterproof - ideal for underwater use. |
Regular
|
Probe Model:
|
FS
|
NS
|
FNS
|
NAS
|
FTS
|
![]() |
||||||
Range:
|
0 - 60 mils | 0 -25 mils | 0 -250 mils | |||
0 - 1500 um | 0 - 625 um | 0 - 6 mm | ||||
Accuracy*:
|
+ (0.05 mils + 1%) 0 - 2 mils + (0.1 mils + 1%) > 2 mils |
+ (0.02 mils + 1%) 0 - 4 mils + (0.1 mils + 3%) > 4 mils |
+ (0.5 mils + 1%) 0 - 100 mils + (0.5 mil + 3%) > 100 mils |
|||
+ (1 um + 1%) 0 - 50 um + (2 um + 1%) > 50 um |
+ (.5 um + 1%) 0 - 100 um + (2 um + 3%) > 100 um |
+ (0.01 mm + 1%) 0 - 2.5 mm |
||||
*Accuracies are stated as a fixed value plus a percentage of the gage's actual reading. |
|
Separate 90° Regular Probes Right angle probe for measuring within areas of low headroom. These constant-pressure, stainless steel probes are hermetically sealed to be totally waterproof - ideal for underwater use. |
90 Regular
|
Probe Model:
|
FRS
|
NRS
|
FNRS
|
![]() |
||||
Range:
|
0 - 60 mils | |||
0 - 1500 um | ||||
Accuracy*:
|
+ (0.05 mils + 1%) 0 - 2 mils + (0.1 mils + 1%) > 2 mils |
|||
+ (1 um + 1%) 0 - 50 um + (2 um + 1%) > 50 um |
||||
*Accuracies are stated as a fixed value plus a percentage of the gage's actual reading. |
![]()
|
Separate 0° Microprobes With our smallest measuring tip and best thin-film accuracy, this instrument is ideal for measuring on small parts, hard-to-reach areas, or close to edges. |
The straight F0S and N0S Microprobes have a quick release adapter that makes them constant pressure probes for alignment on small, flat or curved parts. This adapter is held in place by a spring. If the sleeve is not required, simply pull it off the probe. | |
0 Microprobe
|
Probe Model:
|
F0S
|
N0S
|
![]() ![]() |
|||
Range:
|
0 - 45 mils | 0 - 25 mils | |
0 - 1150 um | 0 - 625 um | ||
Accuracy*:
|
+ (0.02 mils + 1%) 0 - 4 mils + (0.1 mils + 3%) > 4 mils |
||
+ (.5 um + 1%) 0 - 100 um + (2 um + 3%) > 100 um |
|||
*Accuracies are stated as a fixed value plus a percentage of the gage's actual reading. |
![]() |
Separate 45°Microprobes With our smallest measuring tip and best thin-film accuracy, this instrument is ideal for measuring on small parts, hard-to-reach areas, or close to edges. |
45 Microprobe
|
Probe Model:
|
F45S
|
N45S
|
![]() |
|||
Range:
|
0 - 45 mils | 0 - 25 mils | |
0 - 1150 um | 0 - 625 um | ||
Accuracy*:
|
+ (0.02 mils + 1%) 0 - 4 mils + (0.1 mils + 3%) > 4 mils |
||
+ (.5 um + 1%) 0 - 100 um + (2 um + 3%) > 100 um |
|||
*Accuracies are stated as a fixed value plus a percentage of the gage's actual reading. |
|
Separate 90° Microprobes Right angle probe for measuring within areas of low headroom. With our smallest measuring tip and best thin-film accuracy, this instrument is ideal for measuring on small parts, hard-to-reach areas, or close to edges. |
90 Microprobe
|
Probe Model:
|
N90S
|
![]() |
||
Range:
|
0 - 45 mils | 0 - 25 mils |
0 - 1150 um | 0 - 625 um | |
Accuracy*:
|
+ (0.02 mils + 1%) 0 - 4 mils + (0.1 mils + 3%) > 4 mils |
|
+ (.5 um + 1%) 0 - 100 um + (2 um + 3%) > 100 um |
||
*Accuracies are stated as a fixed value plus a percentage of the gage's actual reading. |
![]()
|
High-Range Probes Ideal for thick protective coatings such as epoxy, rubber, concrete liners, intumescent fireproofing and more. |
High-Range
|
Probe Model:
|
FT
|
FTS |
FNTS
|
FKS
|
NKS
|
||
|
![]() |
![]() |
||||||
Range:
|
0 -250 mils | 0 -500 mils | ||||||
0 - 6 mm | 0 - 13 mm | |||||||
Accuracy*:
|
+ (0.5 mils + 1%) 0 - 100 mils + (0.5 mil + 3%) > 100 mils |
+ (1 mils + 3%)
+ (0.02 mm + 3%) |
||||||
+ (0.01 mm + 1%) 0 - 2.5 mm |
||||||||
FT | FTS | FNTS,FKS,NKS | *Accuracies are stated as a fixed value plus a percentage of the gage's actual reading. |
Probe Details: Several probe configurations are available for measuring a wide variety of coating thickness application.
Removable Built-in probes
Removable
Built-in Probe |
Probe Model:
|
F
|
N
|
FN
|
FT
|
---|---|---|---|---|---|
![]() |
|||||
Range:
|
0 - 60 mils | 0 -250 mils | |||
0 - 1500 um | 0 - 6 mm | ||||
Accuracy*:
|
+ (0.05 mils + 1%) 0 - 2 mils + (0.1 mils + 1%) > 2 mils |
+ (0.5 mils + 1%) 0 - 100 mils + (0.5 mil + 3%) > 100 mils |
|||
+ (1 um + 1%) 0 - 50 um + (2 um + 1%) > 50 um |
+ (0.01 mm + 1%) 0 - 2.5 mm |
||||
*Accuracies are stated as a fixed value plus a percentage of the gage's actual reading. |
Separate Regular Probes (below regular probes suitable for underwater use)
Regular
|
Probe Model:
|
FS
|
NS
|
FNS
|
NAS
|
FTS
|
---|---|---|---|---|---|---|
![]() |
||||||
Range:
|
0 - 60 mils | 0 -25 mils | 0 -250 mils | |||
0 - 1500 um | 0 - 625 um | 0 - 6 mm | ||||
Accuracy*:
|
+ (0.05 mils + 1%) 0 - 2 mils + (0.1 mils + 1%) > 2 mils |
+ (0.02 mils + 1%) 0 - 4 mils + (0.1 mils + 3%) > 4 mils |
+ (0.5 mils + 1%) 0 - 100 mils + (0.5 mil + 3%) > 100 mils |
|||
+ (1 um + 1%) 0 - 50 um + (2 um + 1%) > 50 um |
+ (.5 um + 1%) 0 - 100 um + (2 um + 3%) > 100 um |
+ (0.01 mm + 1%) 0 - 2.5 mm |
||||
*Accuracies are stated as a fixed value plus a percentage of the gage's actual reading. |
90 Regular
|
Probe Model:
|
FRS
|
NRS
|
FNRS
|
---|---|---|---|---|
![]() |
||||
Range:
|
0 - 60 mils | |||
0 - 1500 um | ||||
Accuracy*:
|
+ (0.05 mils + 1%) 0 - 2 mils + (0.1 mils + 1%) > 2 mils |
|||
+ (1 um + 1%) 0 - 50 um + (2 um + 1%) > 50 um |
||||
*Accuracies are stated as a fixed value plus a percentage of the gage's actual reading. |
Separate Microprobes
0 Microprobe
|
Probe Model:
|
F0S
|
N0S
|
---|---|---|---|
![]() ![]() |
|||
Range:
|
0 - 45 mils | 0 - 25 mils | |
0 - 1150 um | 0 - 625 um | ||
Accuracy*:
|
+ (0.02 mils + 1%) 0 - 4 mils + (0.1 mils + 3%) > 4 mils |
||
+ (.5 um + 1%) 0 - 100 um + (2 um + 3%) > 100 um |
|||
*Accuracies are stated as a fixed value plus a percentage of the gage's actual reading. |
45 Microprobe
|
Probe Model:
|
F45S
|
N45S
|
---|---|---|---|
![]() |
|||
Range:
|
0 - 45 mils | 0 - 25 mils | |
0 - 1150 um | 0 - 625 um | ||
Accuracy*:
|
+ (0.02 mils + 1%) 0 - 4 mils + (0.1 mils + 3%) > 4 mils |
||
+ (.5 um + 1%) 0 - 100 um + (2 um + 3%) > 100 um |
|||
*Accuracies are stated as a fixed value plus a percentage of the gage's actual reading. |
90 Microprobe
|
Probe Model:
|
F90S
|
N90S
|
---|---|---|---|
![]() |
|||
Range:
|
0 - 45 mils | 0 - 25 mils | |
0 - 1150 um | 0 - 625 um | ||
Accuracy*:
|
+ (0.02 mils + 1%) 0 - 4 mils + (0.1 mils + 3%) > 4 mils |
||
+ (.5 um + 1%) 0 - 100 um + (2 um + 3%) > 100 um |
|||
*Accuracies are stated as a fixed value plus a percentage of the gage's actual reading. |
Separate High-Range Probes
High-Range
|
Probe Model:
|
FNTS
|
FKS
|
NKS
|
---|---|---|---|---|
![]() |
||||
Range:
|
0 -250 mils | 0 -500 mils | ||
0 - 6 mm | 0 - 13 mm | |||
Accuracy*:
|
+ (0.5 mils + 1%) 0 - 100 mils + (0.5 mil + 3%) > 100 mils |
+ (1 mils + 3%) 0 - 500 mils + (0.02 mm + 3%) 0 - 13 mm |
||
+ (0.01 mm + 1%) 0 - 2.5 mm |
||||
*Accuracies are stated as a fixed value plus a percentage of the gage's actual reading. |